Generation   Home

Heater & Airconditioner/Ventilator • HVAC System (Heater, Ventilator and A/C) • Relay and Fuse • Inspection 2015 Subaru Forester

generation: → 2011 - 2016Release year → 2015 ✔ engine size → 2L ✔      add to compare      read later

HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > Relay and Fuse

INSPECTION

1. CHECK FUSE

1. Remove the fuse and inspect visually.

2. If the fuse is blown out, replace the fuse.

NOTE:

If the fuse is blown again, check the system wiring harness.

2. CHECK RELAY

1. Check the resistance between relay terminals.

• A/C relay

Terminal No.

Inspection conditions

Standard

Circuit

1 — 2

Always

1 M? or more

2015 Subaru Forester Heater & Airconditioner/Ventilator • HVAC System (Heater, Ventilator and A/C) • Relay and Fuse • Inspection

1 — 2

Apply battery voltage between terminals 4 and 3.

Less than 1 ?

• Blower motor relay

Terminal No.

Inspection conditions

Standard

Circuit

1 — 4

Always

1 M? or more

2015 Subaru Forester Heater & Airconditioner/Ventilator • HVAC System (Heater, Ventilator and A/C) • Relay and Fuse • Inspectionac

1 — 4

Apply battery voltage between terminals 2 and 3.

Less than 1 ?

2. Replace the relay if the inspection result is not within the standard.

    2017-02-20 18:50:35    2017-05-11 10:18:54




I advise you to watch 2011 - 2016

© 2018. suforester.com
Order call back